Price 100-300000 INR/ Unit

Water Hammer Damper Specification

  • Connection Type
  • Flanged, Wafer
  • Valve Type
  • Water Hammer Damper
  • Valve Size
  • 2 to 24 (DN50 to DN600)
  • Structure
  • Double flange or wafer type body, with dampening mechanism
  • Application
  • Used for preventing water hammer in pipelines and hydraulic systems
  • Power
  • Not required (mechanical operation)
  • Pressure
  • PN10, PN16, PN25
  • Media
  • Water, Neutral Liquids, Sewage
  • Port Size
  • Available from DN50 to DN600
  • Disc
  • Ductile Iron with Epoxy or Stainless Steel
 

Water Hammer Damper Trade Information

  • Minimum Order Quantity
  • 1 Unit
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 1 Week
 

About Water Hammer Damper

Water Hammer Damper

HYDRAULIC FEATURES
The "HAMMER STOP" device has been designed in order to attenuate the "water hammer" phenomenon which is created in a closed conduct when there is a abrupt variation of the fluid speed. This phenomenon presents itself when there is quick sequence of pressure excesses and drops which creates instability and generates noise and which can provoke serious damages to the systems and the connected devices.

The water hammer damper must be installed near to the devices which can trigger this event such as ball valves, solenoid valves, mixing valves and all hydraulic components capable of stopping the water flow in the pipelines in a sudden way. The norm UNI 9182 "Installations for the alimentation and distribution of cold and hot water. Criteria regarding design, tests and management" recommends the use of a water hammer damper.
TECHNICAL FEATURES
Pressures : 
Static working pressure 3 bar
Maximum working pressure (PN) 10 bar
Maximum water hammer 50 bar
Temperature : 
Maximum working temperature (TS) 90 C
Compatible fluids : 
Water 
Threading:  
Pipeline connection  Threads according to ISO 228/1
Requirements and tests as per :  
Shell tightness  Test P11 - EN 12266-1
Requirements and tests as per worksheet KIWA BRL K632/03
DESIGN
Body in brass EN 12165 - CW617N chrome plated with ELECTRODEPOSITED COATING EN 12540 (Cu/Ni5sCrr)
Damper in brass EN12165-CW602N (DZR)
SM GALVANIZED STEEL calibration spring - EN 10270-1M
Static and dynamic sealing gaskets in EPDM "perox"
PRODUCT CODE
0198.015 male "
0198 . "
WATER HAMMER DAMPER "HAMMER STOP"
CONNECTION: MALE
Features (external dimensions)

Features Table

Features (external dimensions)

WATER HAMMER DAMPER

 

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Water Hammer Damper Category

Smoke Dampers Series SD

Smoke Dampers Series SD

Price 100-300000 INR / Unit

Minimum Order Quantity : 1 Unit

Sealing : Leakage Class I/II as per standards

Type : Motorized Smoke Damper

Voltage : 24V/230V AC or DC

Port Size : Custom sizes as per duct requirements



Back to top